  Datasheet File OCR Text:
  c-series circuit breaker parallel pole actuator metal toggle actuator handle actuator agency certifcations: ul recognized ul standard 1077 | ul standard 508 ul standard 1500 ul listed ul standard 489 | ul standard 489a csa accepted | csa certifed tuv certifed | vde certifed * for full agency certifcations, please see pg. 6 the c-series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. they are available in 1-6 poles, 0.02-100amps, ul recognized up to 480vac or 150vdc, ul489 listed up to 240vac or 125vdc, with choice of time delays, terminal options, actuator styles and colors. product highlights: ? the ul489 c-series employs a unique arc chute design which allows for higher interrupting capacities of up to 10,000 amps. new thermoset glass flled polyester half shell construction provides for increased mechanical and electrical strength. the wiping contacts, mechanical linkage with two step actuation, clean contacts providing high, positive contact pressure and longer contact life ? available with american standard or metric threaded stud terminals, or saddle clamp screw terminals. optional mid-trip handle style actuator allows visual indication of electrical overload with or without alarm feature ? available with new solid color rocker actuators and unique two-color visi-rocker? actuators, which can be specifed to indicate either the on or tripped/off mode ? exclusive rockerguard and push-to-reset bezel help prevent inadvertent actuation carling technologies, inc. 60 johnson avenue ? plainville, ct 06062-1177 phone: (860) 793-9281 ? fax: (860) 793-9231 email: sales@carlingtech.com ? www.carlingtech.com
150 150 80-100 tc1, olo, u3 agency code l agency code l parallel pole tc, olo, u3 101-175 2 | c-series C general specifcations electrical tables table a: lists ul recognized & csa accepted confgurations and performance capabilities as a component supplementary protector notes for table a: 1 requires branch circuit backup with a ul listed type k5 or rk5 fuse rated 15a minimum and no more than 4 times full load amps not to exceed 125a for 50 amp or less rating and not to exceed 175 for 51 through 100 amp rating *manufacturer reserves the right to change product specification without prior notice. 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
c-series C general specifcations | 3 electrical tables table b: lists ul recognized and csa accepted confgurations and performance capabilities as a manual motor controller. table c: lists ul recognized, csa accepted , vde and tuv certifed confgurations and performance capabilities as a component supplementary protector. notes for table b: 1 ul recognized and csa accepted at 480v refers to 3 & 4 pole versions used in a 3?, wye connected circuit or 2-pole version connected with 2 poles breaking. 1? and backed up with series fusing as stated above in note 1. * series, shunt and relay trip - voltage coil construction not current coils notes for table c: 1 general purpose ratings for ul/csa only. 2 requires branch circuit backup with a ul listed type k5 or rk5 fuse rated 15a minimum and no more than 4 times full load amps not to exceed 125a for 50 amp or less rating and not to exceed 175 for 51 through 100 amp rating. rela y 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
4 | c-series C general specifcations electrical tables table d: lists ul listed (489), csa certifed (c22.2 no. 5.1-m) confguration and performance capabilities as a molded case circuit breaker. table e: lists ul recognized, csa accepted confgurations and performance capabilities as protectors, supplementary for marine electrical and fuel systems (guide peqz2, file e75596). ignition protected per ul 1500. ul classifed small craft electrical devices, marine in accordance with iso 8846 (guide uzmk, file mq1515) as marine supplementary protectors. table f: lists ul listed confgurations and performance capabilities as circuit breakers for use in communications equipment (guide ditt, file e189195), under ul489a. notes from table d: 1 special catalog number required. consult factory. current ra ting interrupting capa city (amps) 50,000 1 limited to 2 poles max from 71 - 100 amps. 10,000 limited to 2 poles max from 71 - 100 amps. 125 dc --- 0.10 - 100 5,000 1 - 3 poles 125 / 250 dc --- 0.10 - 50 5,000 1 or 2 poles (2 poles required for 250 v olts) 0.10 - 50 10,000 1 - 3 poles 51 - 70 5,000 1 - 3 poles 0.10 - 50 5,000 2 or 3 poles. 1 pole of a 3 pole unit is neutra l 0.10 - 50 10000 1 2 or 3 poles. 1 pole of a 3 pole unit is neutra l 240 50 / 60 10 .10 - 30 5,000 1pol e 240 50 / 60 10 .10 - 20 5,000 2 pole 277 50 / 60 10 .10 - 20 10,000 1pol e dual coil 120 50 / 60 10 .10 - 30 10,000 --- circuit configura tion full load amps phase voltage 1 0.10 - 100 50 / 60 1 120 / 240 dc construction notes c series t able d : ul489 listed branch circuit breakers series 120 80 50 / 60 without backup fuse max. ra ting frequency --- 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
c-series C general specifcations | 5 mechanical physical environmental electrical maximum voltage current rating standard voltage coils auxiliary switch rating insulation resistance dielectric strength resistance, impedance pulse tolerance curves endurance trip free trip indication number of poles internal circuit confguration weight standard colors shock vibration moisture resistance salt spray thermal shock operating temperature designed and tested in accordance with requirements of specifcation mil-prf-55629 & mil-std-202 as follows: ac, 480 wye/277 vac, 50/60 hz (see table a.) ul489: ac,240 vac. ( table d ) , 50/60 hz, 125 vdc, ul 1077, 150 vdc, 277 vac standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 25.0, 30.0, 35.0, 40.0, 50.0, 60.0, 70.0, 80.0, 90.0 and 100 amps. other ratings available, see ordering scheme. dc - 6v, 12v; ac - 120v; other ratings available, see ordering scheme. spdt; 10.1 amps-250vac, dc aux. switch 1.0a, 65 vdc. 0.5a, 80vdc,1/4 hp, 125vac,vde & tuv 1.0 125 vac. minimum of 100 megohms at 500 vdc . ul, csa: 1960 v 50/60 hz for one minute between all electrically isolated terminals. c-series circuit breakers comply with the 8mm spacing and 3750v 50/60 hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per publications en 60950 and vde 0805. values from line to load terminal based on series trip circuit breaker. 10,000 on-off operations @ 6 per minute; with rated current & voltage all c-series circuit breakers will trip on overload, even when actuator is forcibly held in the on position. the operating actuator moves positively to the off position when an overload causes the breaker to trip. with mid-trip, handle moves to the mid position on electrical trip of the circuit breaker. with mid trip handle with alarm switch, handle moves to the mid position and the alarm switch actuates when the circuit breaker is electrically tripped. 1-6 poles 50a; 1-4 poles @ 51- 70a; 1-2 poles 71-100a. ul489 handle: 1 pole 100a, 2 pole 50a; rocker: 1 pole 100a. series (with or without auxiliary switch, mid trip & mid trip with alarm switch) shunt & relay with current or voltage trip coils, dual coil, switch only (with or without aux. switch). ul489: series (with or without auxiliary switch, mid-trip & mid-trip with alarm switch). approx.112 grams/pole ( 3.95 oz). housing: black withstands 100 gs, 6ms sawtooth while carrying rated current per method 213, test condition i. instantaneous and ultrashort curves tested @ 90% of rated current. withstands 0.060 excursion from 10-55 hz & 10 gs 55-500 hz, @ rated current per method 204c, test cond. a. instantaneous & ultrashort curves tested @ 90% of rated current. method 106d, i.e., ten 24-hour cycles @ +25c to +65c, 80-98% rh. method 101, condition a (90-95% rh @ 5% nacl solution, 96 hrs). method 107d, condition a (fve cycles @ -55c to +25c to +85c to +25c). -40c to +85c 0.1 0.1 0.01 0.001 0.01 1 10 100 1000 15% 25% 35% 1 100  10 t olerance (%) o h m s current (amps) figure 1 0.100 - 5.0  5.1 - 20.0 20.1 - 100 resist ance, imped ance v alues from line to load te r minals (v alues based on ser ies tr ip circuit break er ) ampere ra ting  time dela y cur ve s 42, 44 & 46 (50 amps max.) 16.67 t multiple of rated current r i 4.165 8.33 25x 12x 20.0 time dela y cur ve s 22, 24 (100 amps max.) 26 (70 amps max.) time in  milliseconds t time dela y cur ve s 22, 24 (100 amps max.) 26 (70 amps max.) 60 hz 1/2 cyc le inrush pulse t olerance 50 hz 1/2 cyc le inrush pulse t olerance 10.0 time dela y cur ve s 42, 44 & 46 (50 amps max.) 22x 10x multiple of rated current 5.0 r i time dela y cur ve s 42, 44 & 46 (50 amps max.) 16.67 t multiple of rated current r i 4.165 8.33 25x 12x 20.0 time dela y cur ve s 22, 24 (100 amps max.) 26 (70 amps max.) time in  milliseconds t time dela y cur ve s 22, 24 (100 amps max.) 26 (70 amps max.) 60 hz 1/2 cyc le inrush pulse t olerance 50 hz 1/2 cyc le inrush pulse t olerance 10.0 time dela y cur ve s 42, 44 & 46 (50 amps max.) 22x 10x multiple of rated current 5.0 r i current (amps) 0.10 - 5.0 5.1 - 20.0 15% 25% t olerance (%) 20.1 - 100.0 35% 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
6 | c-series - agency certifcations agency certifcations: ul recognized ul standard 1077 component recognition program as protectors, supplementary (guide ccn/qvnu2, file e75596) ul standard 508 motor controllers, manual (guide ccn/nlrv2, file e135367) ul standard 1500 protectors, supplementary for marine electrical & fuel systems (guide peqz2, file e75596) ignition protection ul listed ul standard 489 circuit breakers, molded case, (guide divq, file e129899) ul standard 489a communications equipment (guide ccn/ditt, file e189195) csa accepted component supplementary protector under class 3215 30, file 047848 0 000 csa standard c22.2 no. 235 csa certifed circuit breaker model case (class 1432 01, file 093910), csa standard c22.2 no. 5.1 - m tuv certifed en60934, under license no. r72041016 vde certifed en60934, vde 0642 under file no. 10537 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
c-series handle ul recognized C ordering scheme | 7 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting bezel/barrier 11 agency approval 4 circuit notes: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 actuator code: a: handle tie pin spacer(s) and retainers provided assembled with multi-pole units. b: handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles s: handle moves to mid-position only upon electrical trip of the breaker. available with circuit codes b, c, d, e, f, g, h and k. t: handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. available with circuit codes b & c. standard multipole units have all poles identical except when specifying auxilary switch and/or mixed poles. 4 pole max w/vde. 5th pole available as series trip w/voltage coil only. switch only circuits, rated up to 50 amps and 6 poles, and only available with vde certi - fcation when tied to a protected pole (circuit code b, c, d or h.). for .02 to 30 amps, select current code 630. for 35 - 50 amps, select current code 650. for 55-70 amps, select current code 670. for 75-100 amps, select current code 810. circuit codes d,e,f,g,h & k available with terminal codes 1,2,4 & 5 only. circuit codes d, f, h & k available up to 50 amps maximum current rating. consult factory for available dual coil options, as special catalog number is required. dual coil voltage coils with shunt trip construction trip instantaneously on line voltage. dual coil voltage coils require 30va minimum power to trip instantaneously and are rated for intermittent duty only. ers, one aux. switch is supplied, mounted in the extreme right pole. voltage coils not rated for continuous duty. available only with delay codes 10 and 20. available with circuit codes b & d only, and up to 50 amps maximum. current ratings 60 - 70 are available up to four poles maximum. ratings 71 - 100 are available up to two poles maximum. terminal code 1 available to 60 amps maximum. terminal codes 2,4,5 and c available to 50 amps maximum. terminal codes 3,6 & 9 available to 100 amps maximum. terminal code 7 available to 25 amps maximum. terminal code a available to 100 amps maximum. terminal codes 7,8,9 & c are not vde approved. no marking available. consult factory. vde/tuv approval requires dual (i-o, on-off) or i-o markings on all handles. single pole only. vde/tuv: 30 amps max.; ul/csa: 50 amps max.; available in 2 - 4 poles only and limited to ac delays. general purpose amps not rated for full load amps or to be used in applications with a motor. c a b 1 1 3 0 2 c 10 450 1 series c 2 actuator 1 a handle, one per pole b handle, one per multipole unit s mid-trip handle, one per pole t mid-trip, one per pole & alarm switch 8 terminal 15 1 10 stud 10-32, threaded 2 11 screw 10-32 3 12 screw 1/4-20, threaded 4 11 screw m5 x 0.8, threaded 5 11 screw m5 x 0.8 6 12 screw m6, threaded 7 13,15 0.250 double click connect 8 15 1/4 clip terminal 9 12,15 7/16 clip terminal a 14 plug-in stud c 11,15 5/16 clip terminal 3 poles 2 1 one 2 two 3 three 4 four 5 five 6 six 4 circuit 3 a 3 switch only (no coil) b series trip (current) c series trip (voltage) d 4 shunt trip (current) e 4 shunt trip (voltage) f 4 relay trip (current) g 4 relay trip (voltage) h 4,5 dual coil with shunt trip voltage coil k 4,5 dual coil with relay trip voltage coil 5 auxiliary/alarm switch 0 without aux switch 2 s.p.d.t., 0.110 q.c. terminal 3 s.p.d.t., 0.139 solder lug 4 s.p.d.t., 0.110 q.c. terminal (gold contacts) 6 s.p.s.t., 0.139 solder lug 8 s.p.s.t., 0.187 q.c. terminal 9 s.p.d.t., 0.187 q.c. terminal 6 frequency & delay 03 3 dc 50/60hz, switch only 10 7 dc instantaneous 11 dc ultra short 12 dc short 14 dc medium 16 dc long 20 7 50/60hz instantaneous 21 50/60hz ultra short 22 50/60hz short 24 50/60hz medium 26 50/60hz long 30 dc 50/60hz instantaneous 31 dc 50/60hz ultra short 32 dc 50/60hz short 34 dc 50/60hz medium 36 dc 50/60hz long 42 8 50/60hz short, hi-inrush 44 8 50/60hz medium, hi-inrush 46 8 50/60hz long, hi-inrush 52 8 dc short, hi-inrush 54 8 dc medium, hi-inrush 56 dc long, hi-inrush 7 current rating (amperes) 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 35.000 640 40.000 650 50.000 660 9 60.000 670 9 70.000 680 9 80.000 685 9 85.000 690 9 90.000 695 9 95.000 810 9 100.000 code amperes a06 6dc a12 12dc a18 18dc a24 24dc a32 32dc a48 48dc a65 65dc j06 6ac j12 12ac j18 18ac j24 24ac j48 48ac j65 65ac k20 120ac l40 240ac code rating voltage coil (norminal rated voltage) 7 9 actuator color & legend 16 actuator color white black red green blue yellow gray orange black (short handle) 17 i-o a c f h k m p r t on-off b d g j l n q s u dual 1 2 3 4 5 6 7 8 9 legend color black white white white white black black black white 10 mounting /barriers mounting style threaded insert 6-32 x 0.195 inches 6-32 x 0.195 inches 6-32 x 0.195 inches iso m3 x 5mm iso m3 x 5mm iso m3 x 5mm with handleguard barriers no yes yes no yes yes no 1 a c 18 2 b d 18 e 17 voltage 300 300 300 300 300 300 300 front panel snap-in, 1.00 [25.4mm] wide bezel < < < 11 agency approval c ul recognized, csa accepted d vde certifed, ul recognized, csa accepted e tuv certifed, ul recognized, csa accepted h ul489 construction: vde certifed, ul recognized, csa accepted i ul rec. std 1077, ul rec. 1500 (ignition protected), csa accepted l ul489 construction: ul recognized, csa accepted r ul489 construction: tuv certifed, ul recognized, csa accepted < < > C > C 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
12 agency approval t k 7 ul489a listed (up to 250 amps) ul489a listed, vde certifed (up to 200 amps) ul489a listed, tuv certifed (up to 250 amps) 8 | c-series handle parallel pole ul489a listed C ordering scheme 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting 11 max. app. rating 12 agency approval 4 circuit notes: 1 2 3 actuator code: a: handle tie pin spacer(s) and retainers provided assembled with multi-pole units. s: handle moves to mid-position only upon electrical trip of the breaker. t: handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. terminal code: 3 & 6: supplied with bus bars connecting the line and load terminals. a: line and load terminals must be connected to a copper bus bar having a minimum cross section of 0.078 square inches. above 200 amps, 3 poles are required. c a p 3 1 2 0 2 m t d4 820 1 series c 2 actuator 1 a handle, one per pole s mid-trip handle, one per pole t mid-trip, one per pole & alarm switch 8 terminal 2 3 1/4-20, threaded 6 m6, threaded a plug-in stud 3 poles 3 2 two 3 three 4 circuit p series trip (parallel pole) 6 frequency & delay d1 dc ultra short d2 dc short d4 dc medium d6 dc long 7 current rating (amperes) 811 110.000 812 120.000 912 125.000 813 130.000 814 140.000 815 150.000 816 160.000 817 170.000 917 170.000 818 180.000 819 190.000 820 200.000 922 3 225.000 825 3 250.000 code amperes 9 actuator color white black red green blue yellow gray orange legend color black white white white white black black black legend on-off b d g j l n q s dual 1 2 3 4 5 6 7 8 10 mounting /barriers mounting style threaded insert 6-32 x 0.195 inches iso m3 x 5mm 1 2 11 maximum application rating m 80 dc 5 auxiliary/alarm switch 0 without aux switch 2 s.p.d.t., 0.110 q.c. terminal 3 s.p.d.t., 0.139 solder lug 4 s.p.d.t., 0.110 q.c. terminal (gold contacts) 6 s.p.s.t., 0.139 solder lug 8 s.p.s.t., 0.187 q.c. terminal 9 s.p.d.t., 0.187 q.c. terminal 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
c-series handle ul489 listed C ordering scheme | 9 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 max. app. rating 12agency approval 4 circuit notes: 1 2 3 4 5 6 7 8 9 10 11 12 actuator code: a: handle tie pin spacer(s) and retainers provided assembled with multi-pole units. b: handle located, as viewed from front of breaker in left pole. 2 pole maximum. s: handle moves to mid-position only upon electrical trip of the breaker. t: handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. standard multipole units have all poles identical except when specifying auxiliary switch and/or mixed poles. 2 & 3 pole circuit breakers required for 120/240 vac (maximum application rating code c) applications, have all poles identical except when specifying auxiliary / alarm switch which is normally supplied in extreme right pole per fgure b. terminal barriers are required on all multipole breakers. third pole is for 120/240 vac applications requiring neutral disconnect. the 3rd pole has the same construction as poles 1 & 2. on multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme right pole. vde approval on auxiliary switch codes 2, 3 & 4 only. auxiliary / alarm switch with independent circuit ie: separate from breaker circuit, only available with circuit breakers rated 50 amp maximum at 80 vdc, 125 vdc, and 120 vac. auxiliary / alarm switch with dependent circuit ie: same as circuit breaker, is supplied from factory with common terminal of auxiliary / alarm switch connected to line terminal on 120/240 and 240 vac ratings. circuit breakers rated 120 vac 50 amp maximum can be supplied with auxiliary/alarm switch common terminal connected to breaker line terminal. consult factory for special catalog number. available up to 50 amps maximum. current ratings 71 - 100 with vde approvals are available up to two poles maximum. terminal codes 8, 9 & c are not vde approved. terminal code 1 available to 60 amps maximum. terminal codes 2, 4, 5 & c available to 50 amps maximum. terminal codes 3, 6 & 9 available to 100 amps maximum. terminal code a available to 100 amps maximum. vde and tuv approvals require dual (i-o, on-off) markings on all handles. barriers supplied on multi-pole units only. c a b 1 1 3 0 2 k g 14 450 1 series c 2 actuator 1 a handle, one per pole b handle, one per multipole unit s mid-trip handle, one per pole t mid-trip, one per pole & alarm switch 8 terminal 6 1 7 stud 10-32, threaded 2 8 screw 10-32 3 9 screw 1/4-20, threaded 4 8 screw m5 x 0.8, threaded 5 8 screw m5 x 0.8 6 9 screw m6, threaded 8 1/4 clip terminal 9 9 7/16 clip terminal a 10 plug-in stud c 5/16 clip terminal 3 poles 2 1 one 2 two 3 three 4 circuit b series trip (current) 6 frequency & delay 11 dc ultra short 12 dc short 14 dc medium 16 dc long 21 50/60hz ultra short 22 50/60hz short 24 50/60hz medium 26 50/60hz long 42 4 50/60hz short, hi-inrush 44 4 50/60hz medium, hi-inrush 46 4 50/60hz long, hi-inrush 52 4 dc short, hi-inrush 54 4 dc medium, hi-inrush 56 4 dc long, hi-inrush 7 current rating (amperes) 5 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 35.000 640 40.000 660 60.000 670 70.000 680 80.000 685 85.000 690 90.000 695 95.000 810 100.000 code amperes 9 actuator color & legend 11 actuator color white black red green blue yellow gray orange on-off b d g j l n q s dual 1 2 3 4 5 6 7 8 legend color black white white white white black black black 10 mounting /barriers mounting style threaded insert 6-32 x 0.195 inches iso m3 x 5mm barriers 12 yes yes 1 2 11 maximum application rating a 65 dc b 125 dc c 120/240 ac 2 d 240 ac f 277 ac k 120 ac m 80 dc 12 agency approval 11 a f g j without approvals ul489 listed, vde certifed, csa accepted ul489 listed, csa accepted ul489 listed, tuv certifed, csa accepted 5 auxiliary/alarm switch 3 0 without aux switch 2 s.p.d.t., 0.110 q.c. terminal 3 s.p.d.t., 0.139 solder lug 4 s.p.d.t., 0.110 q.c. terminal (gold contacts) 6 s.p.s.t., 0.139 solder lug 8 s.p.s.t., 0.187 q.c. terminal 9 s.p.d.t., 0.187 q.c. terminal 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
11 agency approval c l i ul recognized, csa accepted ul recognized, csa accepted with listed construction ul recognized, csa accepted, ul1500 ignition protection 10 | c-series sealed toggle ul recognized C ordering scheme 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 legend plate 10 mounting bezel/barrier 11 agency approval 4 circuit notes: 1 2 3 4 5 6 7 8 9 10 11 12 13 actuator code m: handle location as viewed from front of breaker: 2 pole - right pole 3 pole - center pole switch only circuits, rated up to 50 amps and 3 poles, and only available with vde. for .02 to 30 amps, select current code 630. for 35 - 50 amps, select current code 650. for 55-70 amps, select current code 670. for 75-100 amps, select current code 810. circuit codes d,e,f,g,h & k available with terminal codes 1,2,4 & 5 only. consult factory for available dual coil options, as special catalog number is required. dual coil voltage coils with shunt trip construction trip instantaneously on line voltage. dual coil voltage coils require 30va minimum power to trip instantaneously and are rated for intermittent duty only. auxiliary switch available with series trip and switch only circuits. on multi-pole break - ers, one aux. switch is supplied, mounted in the extreme right pole. voltage coils not rated for continuous duty. available only with delay codes 10 and 20. available with circuit codes b & d only, and up to 50 amps maximum. consult factory for current ratings 71-100, in three pole units, available as special catalog number only. terminal code 1 available to 60 amps maximum. terminal codes 2,4,5 and c available to 50 amps maximum. terminal codes 3,6 & 9 available to 100 amps maximum. terminal code 7 available to 25 amps maximum. terminal code a available to 100 amps maximum. c m b 1 1 3 0 0 c 10 450 1 series c 2 actuator 1 m sealed toggle, one per pole 8 terminal 1 9 stud 10-32, threaded 2 10 screw 10-32 3 11 screw 1/4-20, threaded 4 10 screw m5 x 0.8, threaded 5 10 screw m5 x 0.8 6 11 screw m6, threaded 7 12 0.250 double click connect 8 1/4 clip terminal 9 11 7/16 clip terminal a 13 plug-in stud c 10 5/16 clip terminal 3 poles 1 one 2 two 3 three 4 circuit a 2 switch only (no coil) b series trip (current) c series trip (voltage) d 3 shunt trip (current) e 3 shunt trip (voltage) f 3 relay trip (current) g 3 relay trip (voltage) h 3,4 dual coil with shunt trip voltage coil k 3,4 dual coil with relay trip voltage coil 6 frequency & delay 03 2 dc 50/60hz, switch only 10 6 dc instantaneous 11 dc ultra short 12 dc short 14 dc medium 16 dc long 20 6 50/60hz instantaneous 21 50/60hz ultra short 22 50/60hz short 24 50/60hz medium 26 50/60hz long 30 dc 50/60hz instantaneous 31 dc 50/60hz ultra short 32 dc 50/60hz short 34 dc 50/60hz medium 36 dc 50/60hz long 42 7 50/60hz short, hi-inrush 44 7 50/60hz medium, hi-inrush 46 7 50/60hz long, hi-inrush 52 7 dc short, hi-inrush 54 7 dc medium, hi-inrush 56 dc long, hi-inrush 7 current rating (amperes) 9 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 35.000 640 40.000 650 50.000 660 9 60.000 670 9 70.000 680 9 80.000 685 9 85.000 690 9 90.000 695 9 95.000 810 9 100.000 code amperes a06 6dc a12 12dc a18 18dc a24 24dc a32 32dc a48 48dc a65 65dc j06 6ac j12 12ac j18 18ac j24 24ac j48 48ac j65 65ac k20 120ac l40 240ac code rating voltage coil (norminal rated voltage) 7 9 legend plate 0 no legend 10 mounting /barriers mounting style standard hex nut standard hex nut (multi-pole units only) barriers no yes 1 a 5 auxiliary/alarm switch 0 without aux switch 2 s.p.d.t., 0.110 q.c. terminal 3 s.p.d.t., 0.139 solder lug 4 s.p.d.t., 0.110 q.c. terminal (gold contacts) 6 s.p.s.t., 0.139 solder lug 8 s.p.s.t., 0.187 q.c. terminal 9 s.p.d.t., 0.187 q.c. terminal 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
c-series rocker ul recognized C ordering scheme | 11 2 actuator 1 two color visi-rocker c indicate on, vertical legend d indicate on, horizontal legend e indicate on, no legend f indicate off, vertical legend g indicate off, horizontal legend h indicate off, no legend push-to-reset, visi-rocker n indicate off, vertical legend o indicate off, horizontal legend p indicate off, no legend single color j vertical legend k horizontal legend l no legend push-to-reset, single color r vertical legend u horizontal legend v no legend 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 agency approval 4 circuit notes: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 push-to-reset actuators have off portion of rocker shrouded. multi-pole breakers have all poles identical except when specifying aux. switch and/or mixed poles, and have one rocker per breaker. rocker location as viewed from front panel: 2 pole C left pole; 3 pole C center pole. switch only circuits, rated up to 50 amps and 3 poles, and only available with vde certifcation when tied to a protected pole (circuit code b, c, d or h.), for .02 to 30 amps, select current code 630. for 35 - 50 amps, select current code 650. for 55-70 amps, select current code 670. for 75-100 amps, select current code 810. circuit codes d,e,f,g,h & k available with terminal codes 1,2,4 & 5 only. circuit codes d,f,h & k available up to 50 amps maximum current rating. consult factory for available dual coil options, as special catalog number is required. dual coil voltage coils with shunt trip construction trip instantaneously on line voltage. dual coil voltage coils require 30va minimum power to trip instantaneously and are rated for intermittent duty only. auxiliary switch available with series trip and switch only circuits. on multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.auxilary switch codes 2,3 & 4 are vde approved. voltage coils not rated for continuous duty. available only with delay codes 10 and 20. available with circuit codes b & d only, and up to 50 amps maximum. current ratings 60-70 are available up to four poles maximum. ratings 71-100 are available up to two poles maximum. terminal code 1 available to 60 amps maximum. terminal codes 2,4,5 & c available to 50 amps maximum. terminal codes 3,6 & 9 available to 100 amps maximum. terminal code 7 available to 25 amps maximum. terminal code a available to 100 amps maximum. terminal codes 7,8,9 & c are not vde approved. color shown is visi and legend with remainder of rocker black legend on push-to-reset bezel/shroud is white when single color rocker is ordered. dual = on-off/i-o legend with actuator codes c - g, and j, k, n, o, r, & u. none = no legend with actuator codes h, l, p, v. rocker - guard available with actuator codes c - l. push-to-reset available witha ctuator codes n, o, p, r, u, v. vde/tuv approval requires dual (i-o, on-off) or i-o markings on rocker. vde/tuv: 30 amps max.; ul/csa: 50 amps max.; available in 2 - 4 poles only and limited to ac delays. general purpose amps not rated for full load amps or to be used in applications with a motor. c c b 1 1 3 0 2 d 14 450 1 series c 8 terminal 1 10 stud 10-32, threaded 2 11 screw 10-32 3 12 stud 1/4-20, threaded 4 11 stud m5 x 0.8, threaded 5 11 screw m5 x 0.8 6 12 stud m6, threaded 7 13 0.250 double quick connect 8 1/4 clip terminal 9 7/16 clip terminal a 14 plug-in stud c 5/16 clip terminal 3 poles 2 1 one 2 two 3 three 4 circuit a 3 switch only (no coil) b series trip (current) c series trip (voltage) d 4 shunt trip (current) e 4 shunt trip (voltage) f 4 relay trip (current) g 4 relay trip (voltage) h 4,5 dual coil with shunt trip voltage coil k 4,5 dual coil with relay trip voltage coil 6 frequency & delay 03 dc 50/60hz, switch only 10 7 dc instantaneous 11 dc ultra short 12 dc short 14 dc medium 16 dc long 20 7 50/60hz instantaneous 21 50/60hz ultra short 22 50/60hz short 24 50/60hz medium 26 50/60hz long 30 dc 50/60hz instantaneous 31 dc 50/60hz ultra short 32 dc 50/60hz short 34 dc 50/60hz medium 36 dc 50/60hz long 42 8 50/60hz short, hi-inrush 44 8 50/60hz medium, hi-inrush 46 8 50/60hz long, hi-inrush 52 8 dc short, hi-inrush 54 8 dc medium, hi-inrush 56 8 dc long, hi-inrush 10 mounting /barriers 1 standard rocker bezel 6-32 x 0.195 inches 6-32 x 0.195 inches 6-32 x 0.195 inches iso m3 x 5mm iso m3 x 5mm iso m3 x 5mm rockerguard bezel 6-32 x 0.195 inches 6-32 x 0.195 inches 6-32 x 0.195 inches iso m3 x 5mm iso m3 x 5mm iso m3 x 5mm push-to-reset bezel 6-32 x 0.195 inches 6-32 x 0.195 inches 6-32 x 0.195 inches iso m3 x 5mm iso m3 x 5mm iso m3 x 5mm barriers no yes yes no yes yes no yes yes no yes yes no yes yes no yes yes 1 2 3 19 4 5 6 19 a c e 19 g j l 19 b d f 19 h j m 19 11 agency approval c d e h i l r ul recognized, csa accepted vde certifed, ul recognized, csa accepted tuv certifed, ul recognized, csa accepted ul489 construction: vde certifed, ul recognized, csa accepted ul rec. std 1077, ul rec. 1500 (ignition protected), csa accepted ul489 construction: ul recognized, csa accepted ul489 construction: tuv certifed, ul recognized, csa accepted 9 actuator color & legend 16,17,18 color: white black red green blue yellow gray orange on-off b d g j l n q s i-o a c f h k m p r dual/none 1 2 3 4 5 6 7 8 actuator or visi-color marking: marking color: single color rocker/handle black white white white white black black black visi-rocker white n/a red green blue yellow gray orange 7 current rating (amperes) 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 35.000 640 40.000 650 50.000 660 9 60.000 670 9 70.000 680 9 80.000 685 9 85.000 690 9 90.000 695 9 95.000 810 9 100.000 code amperes a06 6dc a12 12dc a18 18dc a24 24dc a32 32dc a48 48dc a65 65dc j06 6ac j12 12ac j18 18ac j24 24ac j48 48ac j65 65ac k20 120ac l40 240ac code rating voltage coil (norminal rated voltage) 7 5 auxiliary/alarm switch 6 0 without aux switch 2 s.p.d.t., 0.110 q.c. terminal 3 s.p.d.t., 0.139 solder lug 4 s.p.d.t., 0.110 q.c. terminal (gold contacts) 6 s.p.s.t., 0.139 solder lug 8 s.p.s.t., 0.187 q.c. terminal 9 s.p.d.t., 0.187 q.c. terminal 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
12 | c-series rocker ul listed C ordering scheme single color code "j" line code "k" line indica te "on" code "c" line line line line code "d" indica te color loca tion horizont al style ver tical style code "g" code "f" r ocker style descriptions indica te "off" 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 max. app. rating 12 agency approval 4 circuit notes: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 multi-pole breakers have all breakers identical except when specifying aux. switch and/ or mixed poles, and have one rocker per breaker. on multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. available up to 50 amps maximum. current ratings 71 - 100 with vde approvals are available up to two poles maximum. terminal code 1 available to 60 amps maximum. terminal codes 2, 4, 5 & c available to 50 amps maximum. terminal codes 3, 6, 9 & a available to 100 amps maximum. terminal codes 8, 9 & c are not vde approved. color shown is visi and legend with remainder of rocker black dual = on-off/i-o legend on actuator. vde and tuv approval requires dual (i-o, on-off) markings on rocker. rockerguard available with all actuator codes. barriers supplied on multi-pole units only. 2 & 3 pole circuit breakers required for 120/240 ac rating. c c b 1 a 3 0 2 k g 14 450 1 series c 2 actuator 1 two color visi-rocker c indicate on, vertical legend d indicate on, horizontal legend f indicate off, vertical legend g indicate off, horizontal legend single color j vertical legend k horizontal legend 8 terminal 1 5 stud 10-32, threaded 2 6 screw 8-32 w/saddle & washer clamps 3 7 stud 1/4-20, threaded 4 6 stud m5 x 0.8, threaded 5 6 screw m5 x 0.8 w/saddle & washer clamps 6 7 stud m6, threaded 8 8 1/4 clip terminal 9 7,8 7/16 clip terminal a 7,8 plug-in stud c 6,8 5/16 clip terminal 3 poles 1 1 one 2 two 3 three 4 circuit b series trip (current) 6 frequency & delay 11 dc ultra short 12 dc short 14 dc medium 16 dc long 21 50/60hz ultra short 22 50/60hz short 24 50/60hz medium 26 50/60hz long 42 8 50/60hz short, hi-inrush 44 8 50/60hz medium, hi-inrush 46 8 50/60hz long, hi-inrush 52 8 dc short, hi-inrush 54 8 dc medium, hi-inrush 56 dc long, hi-inrush 7 current rating (amperes) 4 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 35.000 640 40.000 650 50.000 660 60.000 670 70.000 680 80.000 685 85.000 690 90.000 695 95.000 100 100.000 code amperes 10 mounting /barriers 12 standard rocker bezel threaded insert, 2 per pole 6-32 x 0.195 inches iso m3 x 5mm rockerguard bezel threaded insert, 2 per pole 6-32 x 0.195 inches iso m3 x 5mm barriers 13 yes yes yes yes a c b d 11 maximum application rating a 65 dc b 125 dc c 120/240 ac 14 d 240 ac f 277 ac k 120 ac m 80 dc 12 agency approval a f g j without approvals ul 489 listed, csa certifed, & vde certifed ul 489 listed & csa certifed ul489 listed, csa certifed & tuv certifed 9 actuator color & legend 11 color: white black red green blue yellow gray orange on-off b d g j l n q s dual 10 1 2 3 4 5 6 7 8 actuator or visi-color 9 marking: marking color: single color rocker/handle black white white white white black black black visi-rocker white n/a red green blue yellow gray orange 5 auxiliary/alarm switch 2 0 without aux switch 2 s.p.d.t., 0.110 q.c. terminal 3 s.p.d.t., 0.139 solder lug 4 s.p.d.t., 0.110 q.c. terminal (gold contacts) 6 s.p.s.t., 0.139 solder lug 8 s.p.s.t., 0.187 q.c. terminal 9 s.p.d.t., 0.187 q.c. terminal 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
c-series flat rocker ul recognized C ordering scheme | 13 2 actuator 1 two color visi-rocker 1 indicate off, vertical legend 2 indicate off, horizontal legend single color 3 vertical legend 4 horizontal legend push-to-reset, visi-rocker 5 indicate off, vertical legend 6 indicate off, horizontal legend push-to-reset , single color 7 vertical legend 8 horizontal legend 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 agency approval 4 circuit notes: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 push-to-reset actuators have off portion of rocker shrouded. multi-pole breakers have all poles identical except when specifying aux. switch and/or mixed poles, and have one rocker per breaker. rocker location as viewed from front panel: 2 pole C left pole; 3 pole C center pole. switch only circuits, rated up to 50 amps and 3 poles, and only available with vde certifcation when tied to a protected pole (circuit code b, c, d or h.). for .02 to 30 amps, select current code 630. for 35 - 50 amps, select current code 650. for 55-70 amps, select current code 670. for 75-100 amps, select current code 810. circuit codes d,e,f,g,h & k available with terminal codes 1,2,4 & 5 only. circuit codes d,f,h & k available up to 50 amps maximum current rating. consult factory for available dual coil options, as special catalog number is required. dual coil voltage coils with shunt trip construction trip instantaneously on line voltage. dual coil voltage coils require 30va minimum power to trip instantaneously and are rated for intermittent duty only. auxiliary switch available with series trip and switch only circuits. on multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.auxilary switch codes 2,3 & 4 are vde approved. voltage coils not rated for continuous duty. available only with delay codes 10 and 20. available with circuit codes b & d only, and up to 50 amps maximum. current ratings 60-70 are available up to four poles maximum. current ratings 71 - 100 are available up to two poles maximum. terminal code 1 available to 60 amps maximum. terminal codes 2,4,5 & c available to 50 amps maximum. terminal codes 3,6 & 9 available to 100 amps maximum. terminal code 7 available to 25 amps maximum. terminal code a available to 100 amps maximum. terminal codes 7,8,9 & c are not vde approved. color shown is visi & legend with remainder of rocker black. dual = on-off/i-o legend. legend on push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator codes 5 & 6. vde/tuv approval requires dual (i-o, on-off) or i-o markings on rocker. vde/tuv: 30 amps max.; ul/csa: 50 amps max.; available in 2 & 3 poles only and limited to ac delays. general purpose amps not rated for full load amps or to be used in applications with a motor. recessed off side available with actuator codes 1,2,3&4. legends on rocker are available in ink stamping only. c 1 b 1 1 2 0 2 e 10 450 1 series c 8 terminal 1 10 stud 10-32, threaded 2 11 screw 10-32 3 12 stud 1/4-20, threaded 4 11 stud m5 x 0.8, threaded 5 11 screw m5 x 0.8 6 12 stud m6, threaded 7 13 0.250 double quick connect 8 1/4 clip terminal 9 7/16 clip terminal a 14 plug-in stud c 5/16 clip terminal 3 poles 2 1 one 2 two 3 three 4 circuit a 3 switch only (no coil) b series trip (current) c series trip (voltage) d 4 shunt trip (current) e 4 shunt trip (voltage) f 4 relay trip (current) g 4 relay trip (voltage) h 4,5 dual coil with shunt trip voltage coil k 4,5 dual coil with relay trip voltage coil 6 frequency & delay 03 dc 50/60hz, switch only 10 7 dc instantaneous 11 dc ultra short 12 dc short 14 dc medium 16 dc long 20 7 50/60hz instantaneous 21 50/60hz ultra short 22 50/60hz short 24 50/60hz medium 26 50/60hz long 30 dc 50/60hz instantaneous 31 dc 50/60hz ultra short 32 dc 50/60hz short 34 dc 50/60hz medium 36 dc 50/60hz long 42 8 50/60hz short, hi-inrush 44 8 50/60hz medium, hi-inrush 46 8 50/60hz long, hi-inrush 52 8 dc short, hi-inrush 54 8 dc medium, hi-inrush 56 8 dc long, hi-inrush 10 mounting /barriers 1 standard rocker bezel 6-32 x 0.195 inches 6-32 x 0.195 inches 6-32 x 0.195 inches iso m3 x 5mm iso m3 x 5mm iso m3 x 5mm recessed off rocker 6-32 x 0.195 inches 6-32 x 0.195 inches 6-32 x 0.195 inches iso m3 x 5mm iso m3 x 5mm iso m3 x 5mm push-to-reset bezel 6-32 x 0.195 inches 6-32 x 0.195 inches 6-32 x 0.195 inches iso m3 x 5mm iso m3 x 5mm iso m3 x 5mm barriers no yes yes no yes yes no yes yes no yes yes no yes yes no yes yes 1 2 3 19 4 5 6 19 7 8 9 a c e b d f 19 h j m 19 11 agency approval c e i l r ul recognized, csa accepted tuv certifed, ul recognized, csa accepted ul rec. std 1077, ul rec. 1500 (ignition protected), csa accepted ul489 construction: ul recognized, csa accepted ul489 construction: tuv certifed, ul recognized, csa accepted 9 actuator color & legend 16,17,18 color: white black red green blue yellow gray orange on-off b d g j l n q s i-o a c f h k m p r dual/none 1 2 3 4 5 6 7 8 actuator or visi-color marking: marking color: single color rocker/handle black white white white white black black black visi-rocker white n/a red green blue yellow gray orange 7 current rating (amperes) 9 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 35.000 640 40.000 650 50.000 660 9 60.000 670 9 70.000 680 9 80.000 685 9 85.000 690 9 90.000 695 9 95.000 810 9 100.000 code amperes a06 6dc a12 12dc a18 18dc a24 24dc a32 32dc a48 48dc a65 65dc j06 6ac j12 12ac j18 18ac j24 24ac j48 48ac j65 65ac k20 120ac l40 240ac code rating voltage coil (norminal rated voltage) 7 voltage 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 < < < < < < < < < < < < > C > C > C > C > C > C 5 auxiliary/alarm switch 6 0 without aux switch 2 s.p.d.t., 0.110 q.c. terminal 3 s.p.d.t., 0.139 solder lug 4 s.p.d.t., 0.110 q.c. terminal (gold contacts) 6 s.p.s.t., 0.139 solder lug 8 s.p.s.t., 0.187 q.c. terminal 9 s.p.d.t., 0.187 q.c. terminal 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
14 | c-series flat rocker ul listed C ordering scheme 2 actuator 1 two color visi-rocker 1 indicate off, vertical legend 2 indicate off, horizontal legend single color 3 vertical legend 4 horizontal legend push-to-reset, visi-rocker 5 indicate off, vertical legend 6 indicate off, horizontal legend push-to-reset , single color 7 vertical legend 8 horizontal legend 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 max. app. rating 12 agency approval 4 circuit notes: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 push-to-reset actuators have off portion of rocker shrouded. multi-pole breakers have all breakers identical except when specifying aux. switch and/ or mixed poles, and have one rocker per breaker. on multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. available up to 50 amps maximum. current ratings 71 - 100 with vde approvals are available up to two poles maximum. terminal code 1 available to 60 amps maximum. terminal codes 2, 4, 5 & c available to 50 amps maximum. terminal codes 3, 6, 9 & a available to 100 amps maximum. terminal codes 8, 9 & c are not vde approved. color shown is visi and legend with remainder of rocker black dual = on-off/i-o legend on actuator. vde and tuv approval requires dual (i-o, on-off) markings on rocker. legend on push-to-reset bezel/shroud is white when single color rocker is ordered. legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator codes 5 & 6. recessed off-side available with actuator codes 1, 2, 3, & 4. legends on rocker are available in ink stamping only. barriers supplied on multi-pole units only. 2 & 3 pole circuit breakers required for 120/240 ac rating. c 1 b 1 a 2 0 2 k g 14 450 1 series c 8 terminal 1 6 stud 10-32, threaded .625 long 2 7 screw 8-32 w/saddle & washer clamps 3 8 stud 1/4-20, threaded .625 long 4 7 stud m5 x 0.8, threaded .625 long 5 7 screw m5 x 0.8 w/saddle & washer clamps 6 8 stud m6, threaded 17mm long 8 9 1/4 clip terminal 9 8,9 7/16 clip terminal a 8,9 plug-in stud c 7,9 5/16 clip terminal 3 poles 2 1 one 2 two 3 three 4 circuit b series trip (current) 6 frequency & delay 11 dc ultra short 12 dc short 14 dc medium 16 dc long 21 50/60hz ultra short 22 50/60hz short 24 50/60hz medium 26 50/60hz long 42 4 50/60hz short, hi-inrush 44 4 50/60hz medium, hi-inrush 46 4 50/60hz long, hi-inrush 52 4 dc short, hi-inrush 54 4 dc medium, hi-inrush 56 4 dc long, hi-inrush 7 current rating (amperes) 5 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 35.000 640 40.000 650 50.000 660 60.000 670 70.000 680 80.000 685 85.000 690 90.000 695 95.000 100 100.000 code amperes 10 mounting /barriers 12 standard rocker bezel threaded insert, 2 per pole 6-32 x 0.195 inches iso m3 x 5mm recessed off rocker 14 threaded insert, 2 per pole 6-32 x 0.195 inches iso m3 x 5mm push-to-reset bezel threaded insert, 2 per pole 6-32 x 0.195 inches iso m3 x 5mm barriers 15 yes yes yes yes yes yes a c e f b d 11 maximum application rating a 65 dc b 125 dc c 120/240 ac 16 d 240 ac f 277 ac k 120 ac m 80 dc 12 agency approval a without approvals g ul 489 listed & csa certifed j ul489 listed, csa certifed & tuv certifed 9 actuator color & legend 12 color: white black red green blue yellow gray orange on-off b d g j l n q s dual 11 1 2 3 4 5 6 7 8 actuator or visi-color 9 marking: marking color: single color rocker/handle black white white white white black black black visi-rocker white n/a red green blue yellow gray orange 5 auxiliary/alarm switch 2 0 without aux switch 2 s.p.d.t., 0.110 q.c. terminal 3 s.p.d.t., 0.139 solder lug 4 s.p.d.t., 0.110 q.c. terminal (gold contacts) 6 s.p.s.t., 0.139 solder lug 8 s.p.s.t., 0.187 q.c. terminal 9 s.p.d.t., 0.187 q.c. terminal 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
.558 [14.17] .960 [24.38] .311 dia [?7.90] c-series handle C circuit & terminal diagrams | 15 notes: 1 2 3 all dimensions are in inches [millimeters]. tolerance .020 [.51] unless otherwise specifed. available on series trip and switch only circuits when called for on multi-pole units. only one aux. switch is normally supplied, as viewed in mulit-pole identifcation scheme. 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
16 | c-series handle C circuit & terminal diagrams line load notes: 1 2 3 4 all dimensions are in inches [millimeters]. tolerance .020 [.51] unless otherwise specifed. schematic shown represents current trip circuits. available only as special catalog number. 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
c-series handle C form & fit drawings | 17 line load notes: 1 2 all dimensions are in inches [millimeters]. tolerance .020 [.51] unless otherwise specifed. 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
18 | c-series handleguard C form & fit drawings line load notes: 1 2 all dimensions are in inches [millimeters]. tolerance .020 [.51] unless otherwise specifed. 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
c-series parellel pole C form & fit drawings | 19 line load notes: 1 2 all dimensions are in inches [millimeters]. tolerance .020 [.51] unless otherwise specifed. 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
20 | c-series sealed toggle C form & fit drawings line load notes: 1 2 all dimensions are in inches [millimeters]. tolerance .020 [.51] unless otherwise specifed. 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
c-series rocker C circuit & terminal diagrams | 21 line load notes: 1 2 3 all dimensions are in inches [millimeters]. tolerance .020 [.51] unless otherwise specifed. schematic shown represents current trip circuit. 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
22 | c-series rocker C form & fit drawings line load notes: 1 2 3 4 dimensions apply to all variations shown. notice that circuit breaker line and load terminal orientation on indicate off is opposite of indicate on. for pole orientation with horizontal legend, rotate front view clockwise 90. all dimensions are in inches [millimeters]. tolerance .020 [.51] unless otherwise specifed. 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
c-series flat rocker C form & fit drawings | 23 line load notes: 1 2 3 for pole orientation with horizontal legend, rotate front view clockwise 90. all dimensions are in inches [millimeters]. tolerance .020 [.51] unless otherwise specifed. 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com 60 johnson avenue ? plainville, ct 06062C1177 ? phone: (860) 793C9281 ? fax: (860) 793C9231 email: sales @ carlingtech.com ? www.carlingtech.com
worldwide headquarters carling technologies, inc. 60 johnson avenue ? plainville, ct 06062 phone: (860) 793-9281 ? fax: (860) 793-9231 email: sales@carlingtech.com ? www.carlingtech.com east region sales ofce, ct ? ersm@carlingtech.com midwest region sales ofce, il ? mrsm@carlingtech.com west region sales ofce, ca ? wrsm@carlingtech.com asia-pacifc headquarters carling technologies, asia-pacifc ltd., kowloon, hong kong int + 852-2737-2277 ? fax: int + 852-2736-9332 email: sales@carlingtech.com.hk shenzhen, china ? shenzhen@carlingtech.com shanghai, china ? shanghai@carlingtech.com pune, india ? india@carlingtech.com kaohsiung, taiwan ? taiwan@carlingtech.com yokohama, japan ? japan@carlingtech.com europe / middle east / africa headquarters carling technologies, ltd., devon, england int + 44 1392-364422 ? fax: int + 44 1392-364477 email: ltd.sales@carlingtech.com gmbh, germany ? gmbh@carlingtech.com sas, france ? sas@carlingtech.com rev_cb_c_1212


▲Up To Search▲   

 
Price & Availability of CA3-B0-10-450-121-C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X